Your Article Summary
Contrast-enhanced MR angiography with frequency-dependent mask subtraction
Magnetic Resonance Imaging , 07/02/09
Du J et al. - One of the main challenges for high-resolution contrast-enhanced magnetic resonance angiography is the limited signal-to-noise ratio. These partial subtraction techniques were compared with conventional mask subtraction in terms of SNR and artifact power. An SNR gain up to 37% was achieved without significant artifact power increase for quarter-subtraction where only the central one quarter k-space data were subject to mask subtraction.
Related Articles
Dual-Energy CTA with Bone Removal for Transcranial Arteries: Intraindividual Comparison with Standard CTA without Bone Removal and TOF-MRA
Academic Radiology, 10/16/09
Relevance Score: 87%
High-resolution 3D contrast-enhanced MRA with parallel imaging techniques before endovascular interventional treatment of arterial stenosis
Vascular Medicine, 10/12/09
Relevance Score: 87%
Increased volume of coverage for abdominal contrast-enhanced MR angiography with two-dimensional autocalibrating parallel imaging: Initial experience at 3.0 Tesla
Journal of Magnetic Resonance Imaging, 11/10/09
Relevance Score: 84%
Extracoronary Abnormalities on Coronary Magnetic Resonance Angiography in the Multiethnic Study of Atherosclerosis Study: Frequency and Clinical Significance
Journal of Computer Assisted Tomography, 10/13/09
Relevance Score: 84%
Highly accelerated first-pass contrast-enhanced magnetic resonance angiography of the peripheral vasculature: Comparison of gadofosveset trisodium with gadopentetate dimeglumine contrast agents
Journal of Magnetic Resonance Imaging, 10/29/09
Relevance Score: 80%
Today in Angiography...keeping you current
Receive free subspecialty "5-minute updates" via email
Long-Term Results of Angioplasty and Stent Placement for Treatment of Central Venous Obstruction in 126 Hemodialysis Patients: A 10-Year Single-Center Experience
American Journal of Roentgenology, 12/04/09
Computer-Aided Detection of Intracranial Aneurysms in MR Angiography
Journal of Digital Imaging, 12/04/09
Lower Extremity Arterial Injury Patterns and Reconstructive Outcomes in Patients with Severe Lower Extremity Trauma: A 26-Year Review
Journal of the American College of Surgeons, 12/04/09
Today in MRI...keeping you current
Receive free subspecialty "5-minute updates" via email
Diagnostic Value of Multislice Computed Tomography and Magnetic Resonance Imaging in the Diagnosis of Retroperitoneal Spread of Testicular Cancer
Acta Radiologica, 12/04/09
Reperfusion Phenomenon Masking Acute and Subacute Infarcts at Dynamic Perfusion CT: Confirmation by Fusion of CT and Diffusion-Weighted MR Images
American Journal of Roentgenology, 12/04/09
Tears of the Supraspinatus Tendon: Assessment with Indirect Magnetic Resonance Arthrography in 67 Patients with Arthroscopic Correlation
Acta Radiologica, 12/04/09

See Latest Articles