Predictive Value and Safety of Intraoperative Neurophysiological Monitoring With Motor Evoked Potentials in Glioma Surgery
Neurosurgery, 04/30/2012
Krieg SM et al. – Continuous motor evoked potentials (MEPs) monitoring provides reliable monitoring of the motor system, influences the course of operation in some cases, and has to be regarded as the standard for intraoperative neuromonitoring (IOM) of the motor system. In the series, the authors found no false–negative MEP results.