Detection of breast cancer with addition of annual screening ultrasound or a single screening mri to mammography in women with elevated breast cancer risk Full Text
JAMA, 04/05/2012
Clinical Article
Berg WA et al. – The addition of screening ultrasound or MRI to mammography in women at increased risk of breast cancer resulted in not only a higher cancer detection yield but also an increase in false-positive findings.
Methods- From April 2004-February 2006, 2809 women at 21 sites with elevated cancer risk and dense breasts consented to 3 annual independent screens with mammography and ultrasound in randomized order.
- After 3 rounds of both screenings, 612 of 703 women who chose to undergo an MRI had complete data. The reference standard was defined as a combination of pathology (biopsy results that showed in situ or infiltrating ductal carcinoma or infiltrating lobular carcinoma in the breast or axillary lymph nodes) and 12-month follow-up.
- A total of 2662 women underwent 7473 mammogram and ultrasound screenings, 110 of whom had 111 breast cancer events: 33 detected by mammography only, 32 by ultrasound only, 26 by both, and 9 by MRI after mammography plus ultrasound; 11 were not detected by any imaging screen.
- Among 4814 incidence screens in the second and third years combined, 75 women were diagnosed with cancer.
- Supplemental incidence-screening ultrasound identified 3.7 cancers per 1000 screens (95% CI, 2.1-5.8; P < .001).
- Sensitivity for mammography plus ultrasound was 0.76 (95% CI, 0.65-0.85); specificity, 0.84 (95% CI, 0.83-0.85); and PPV3, 0.16 (95% CI, 0.12-0.21).
- For mammography alone, sensitivity was 0.52 (95% CI, 0.40-0.64); specificity, 0.91 (95% CI, 0.90-0.92); and PPV3, 0.38 (95% CI, 0.28-0.49; P < .001 all comparisons).
- Of the MRI participants, 16 women (2.6%) had breast cancer diagnosed.
- The supplemental yield of MRI was 14.7 per 1000 (95% CI, 3.5-25.9; P = .004).
- Sensitivity for MRI and mammography plus ultrasound was 1.00 (95% CI, 0.79-1.00); specificity, 0.65 (95% CI, 0.61-0.69); and PPV3, 0.19 (95% CI, 0.11-0.29).
- For mammography and ultrasound, sensitivity was 0.44 (95% CI, 0.20-0.70, P = .004); specificity 0.84 (95% CI, 0.81-0.87; P < .001); and PPV3, 0.18 (95% CI, 0.08 to 0.34; P = .98).
- The number of screens needed to detect 1 cancer was 127 (95% CI, 99-167) for mammography; 234 (95% CI, 173-345) for supplemental ultrasound; and 68 (95% CI, 39-286) for MRI after negative mammography and ultrasound results.