Relevance of a press-fit dual mobility cup to deal with recurrent dislocation of conventional total hip arthroplasty: a 29-case series

European Journal of Orthopaedic Surgery & Traumatology, 05/11/2012

All patients were reviewed at an average time of 46 ± 28 months. Only one patient had redislocated in this time. This patient underwent a simple closed reduction and did not dislocate again.