McCrea RPE et al. - To improve the interpretation of MRI, author correlated iron accumulation visualized by X-ray fluorescence spectroscopy, an element-specific technique with T1, T2, and susceptibility weighted MR (SWI) in a mouse model of AD. Author show that SWI best shows areas of increased iron accumulation when compared to standard sequences.