The use and efficacy of continuous glucose monitoring in type 1 diabetes treated with insulin pump therapy: a randomised controlled trial

Battelino T et al. – Continuous glucose monitoring was associated with decreased HbA1c levels and time spent in hypoglycaemia in individuals with type 1 diabetes using CSII. More frequent self–adjustments of insulin therapy may have contributed to these effects.

Methods

  • Children and adults (n = 153) on CSII with HbA1c 7.5–9.5% (58.5–80.3 mmol/mol) were randomised to (CGM) a Sensor On or Sensor Off arm for 6 months.
  • After 4 months’ washout, participants crossed over to the other arm for 6 months.
  • Paediatric and adult participants were separately electronically randomised through the case report form according to a predefined randomisation sequence in eight secondary and tertiary centres.
  • The primary outcome was the difference in HbA1c levels between arms after 6 months.

Results

  • Seventy–seven participants were randomised to the On/Off sequence and 76 to the Off/On sequence; all were included in the primary analysis.
  • The mean difference in HbA1c was –0.43% (–4.74 mmol/mol) in favour of the Sensor On arm (8.04% [64.34 mmol/mol] vs 8.47% [69.08 mmol/mol]; 95% CI –0.32%, –0.55% [–3.50, –6.01 mmol/mol]; p < 0.001).
  • Following cessation of glucose sensing, HbA1c reverted to baseline levels.
  • Less time was spent with sensor glucose <3.9 mmol/l during the Sensor On arm than in the Sensor Off arm (19 vs 31 min/day; p = 0.009).
  • The mean number of daily boluses increased in the Sensor On arm (6.8 ± 2.5 vs 5.8 ± 1.9, p < 0.0001), together with the frequency of use of the temporary basal rate (0.75 ± 1.11 vs 0.26 ± 0.47, p < 0.0001) and manual insulin suspend (0.91 ± 1.25 vs 0.70 ± 0.75, p < 0.018) functions.
  • Four vs two events of severe hypoglycaemia occurred in the Sensor On and Sensor Off arm, respectively (p = 0.40).

[more...]

Register now to view all the MDLinx contents (FREE)!

  • Stay current on the latest literature, research and clinical news
  • Get special communications and offers from MDLinx and our sponsors
  • Receive invitations to paid market research
View Samples and Register

Stay current - Media Tool

Newsletter
RSS
Follow Us
Facebook

Receive free subspecialty
"5-minute updates" via email

Sign up!

Send the E-mail Newsletter to a Colleague


Send

Subscribe to our free RSS feeds:
Get the latest news in your specialty automatically added to your newsreader or your personal My Yahoo!, Google, My MSN or My AOL page. Learn More

Follow Us on Twitter
Twitter is a rich source of instantly updated information. Join today and follow @MDLinx to start receiving tweets. Learn More

Close