Elution of monomers from two conventional dental composite materials
Polydorou, O., et al. - The aim of this study was to determine the elution of monomers of two conventional resin composite materials after different polymerization and storage times...Two resin composites (a hybrid and a flowable) were used...No significant difference was found between samples polymerized for 20 s compared to 40 s concerning the elution of monomers. Only a polymerization time of 80 s resulted in a decreased release of monomers. The release of TEGDMA decreased after 28 days; however, the elution of BisGMA remained at high levels [more...]
|
|
|